VSP/HDT


VSP as per ASTM D1525 and HDT as per ASTM D648
COMPUTERISED VSP/HDT TESTER (Model: AE-VSPHDT-2S-C)
  • MOC: Inner – S.S. Outer – M.S.
  • All data entry via software.
  • Average & Standard Deviation.
  • Sample loading: Station easily raised and lowered manually and locked in position avoiding messy oil spills.
  • Deflection/ Penetration: Measured via transducers accurate to 0.00-10.00 mm.
  • Auto cooling system, built in to main bath and auto controlled from Microcontroller.
  • Safety device: Over temperature protection independent of machine control.
  • Standard Model of 2 stations, increasable up to 6 stations.
  • Temperature Range – Ambient to 350°C.
  • Resolution: 0.1°C.
  • Accuracy: +/- 0.1°C.
  • Test Weights - For Vicat: 1 kg and 5 kg. For HDT: Set of 14 modular binary test weights.
  • Temperature ramp rates - 50 °C/h, 120 °C/h.
  • Specimen thickness – 13mm maximum.
  • Fiber stresses – 0.45 Mpa & 1.8 Mpa.
  • Span supports – 100 mm defaults. (others optional)
  • Supply – 230 VAC/ 50 Hz.
  • Paint – Powder coated.



DIGITAL VSP/HDT TESTER (Model: AE-VSPHDT-2S-D)
  • MOC: Inner – S.S.
  • Outer – M.S.
  • Sample loading: Station easily raised and lowered manually and locked in position avoiding messy oil spills.
  • Deflection/ Penetration: Measured on indicator accurately with the resolution 0.01 mm.
  • Oil circulation: Centrifugal stirring system.
  • Safety device: Over temperature protection independent of machine control.
  • Standard Model of 2 stations.
  • Auto cooling system.
  • Temperature Range – Ambient to 350 °C.
  • Resolution: 0.1°C.
  • Accuracy: +/- 0.1°C.
  • Test Weights - For Vicat: 1 kg and 5 kg For HDT: Set of 14 modular binary test weights
  • Temperature ramp rates - 50 °C/h, 120 °C/h.
  • Specimen thickness – 13mm maximum.
  • Fiber stresses – 0.45 Mpa & 1.8 Mpa.
  • Span supports – 100 mm defaults. (others optional)
  • Supply – 230 VAC/ 50 Hz.
  • Paint – Powder coated.


ANALOG VSP/HDT TESTER (Model: AE-VSPHDT-2S-A)
  • MOC: Inner – S.S.Outer – M.S.
  • Sample loading: Station easily raised and lowered manually and locked in position avoiding messy oil spills.
  • Deflection/ Penetration: Measured on dial gauge accurately with the resolution 0.01 mm.
  • Safety device: Over temperature protection independent of machine control.
  • Standard Model of 2 stations.
  • Load calculating calculator will be supplied.
  • Manual cooling system.
  • Temperature Range – Ambient to 350 °C.
  • Resolution: 0.1°C.
  • Accuracy: +/- 0.1°C.
  • Test Weights - For Vicat: 1 kg and 5 kg For HDT: Set of 14 modular binary test weights
  • Temperature ramp rates - 50 °C/h, 120 °C/h.
  • Specimen thickness – 13mm maximum.
  • Fiber stresses – 0.45 Mpa & 1.8 Mpa.
  • Span supports – 100 mm defaults. (others optional)
  • Supply – 230 VAC/ 50 Hz.
  • Paint – Powder coated.